The VLT Cryogenic is a vertical process pump of the "double casing" type as defined by API-610. By multi-staging series stages in the low and medium specific speed design range, the VLT provides outstanding efficiencies and low cost operation in high head applications. The special first stage allows operation with extremely low NPSH requirements while running at optimum speeds. Exclusive hydraulic and mechanical features provide continuing reliability with optimum performance.

CHARACTERISTICS
  • Vertical arrangement.
  • API 610 latest edition.
  • Special sealing system.
  • Low temperature design.
  • Construction materials for Cryogenic Applications.
  • VLT single or multistage.

OPERATION LIMITS

  • Capacity 100 to 1,600 m³/h
    (7,000 U.S. gpm).
  • Head up to 1,220 m (4,000 ft).
  • Maximum Pressure 100 bar (1,500 psi).
  • Temperature -195 to 565 ºC
    (-320 to 1050 ºF).

APPLICATIONS

  • Liquid Nitrogen.
  • Liquid Oxygen.
  • Cryogenic Hydrocarbons.


RUHRPUMPEN NOMENCLATURE

  • VLT Cryogenic






The Global Proposal System (GPS) is Ruhrpumpen's Internet based pump selection system. GPS allows customers to quickly make accurate and detailed pump selections. As it is Internet based, no software is required on the local computer. By entering a set of operating conditions into GPS, all pumps matching those conditions can easily be displayed. From there a performance curve with operating conditions can be created and saved.

The majority of the Ruhrpumpen product catalog has been loaded into GPS. Many lines are available for immediate access without requiring a login. Those product lines shown in gray are only available with a user account.

In addition to the curve selection capability available for public access, GPS provides Ruhrpumpen the ability to generate complete quotation packages internally. This will allow faster responses to customer inquiries.

While GPS is a powerful tool it cannot handle all situations. Certain product lines and conditions are beyond the capabilities of anything but an experienced Application Engineer. Please contact Ruhrpumpen for assistance with any application, small or large.

Usage note: GPS will launch new sessions or pop-ups for user option selection and other functions. Your browser's pop-up settings may require adjustment for these to function properly.